Post Installation tasks and customization at z/OS
The Job-Control which is used by ProcMan Web-Dialog was stored in library HLQ.PROCMAN.SKELS. After installation, you will find all members for sample client HORIZONT. For a new client all example members must be copied with a new name. These new members must be modified according to your company's requirements.
It has proven itself to use the first two characters in member names as client abbreviation. You will be asked for that during the installation dialog. E.g. HO = HORIZONT
HOJADHOC
ADHOC IWS process reformat
HOJAPPT
DSN copy process
HOJAPPV
DSN copy process
HOJCHKC
Verify JCL with Handover type CHANGE
HOJCHKN
Verify JCL with handover type NEW
HOJCPY
Copy members into target library.
HOJDEL
Delete datasets or member
HOJDSNF
Get dataset list
HOJEDT
Jcl Check with “JCL-Check” button. Without Rules.
HOJEDTA
Verify JCL after edit at approve
HOJEDTF
The final JCL check
HOJGDGL
Get list GDG entries
HOJGTYP
Get DSN attributes
HOJJCKT
JCL check with previous IWS variable substitution
HOJOD933
IWS process variable substitution
HOJOSJ
JCL check with TWS variable substitution
HOJPAR1
Used by „Change by Parameters“ function
HOJPAR2
Used by „Change by Parameters“ function
HOJREF
Reformat JCL
HOJREND
HOJUNI
Example job for universal process
HOMEDOW
Fast TSO Export
HOMEUPL
Fast TSO Import
HOOJJCK
IWS process. JCL check with previous IWS variable substitution
HOOJJCKF
IWS process. Final JCL check with previous IWS variable substitution
HOPJCK
Verify procedure IWS variable substitution PO
HOPJCKF
Verify procedure IWS variable substitution fast
HOPCHKC
Verify procedure with handover type CHANGE
HOPCHKN
Verify procedure with handover type NEW
HOPEDT
Check procedure with “JCL-Check” button. Without Rules.
HOPEDTA
Verify procedure after edit at approve
HOPEDTF
The final procedure check
HOPREF
Reformat procedure
The members are skeleton JCL for the ProcMan programs. The dataset names and member names must also be defined in configuration files on ProcMan windows server.
Below you will see an example skeleton.
Variables that are replaced by ProcMan are limited with ‘##’ at the beginning and at the end of a variable. Do not modify or delete these variables.
There are example member with Rules and parameter stored in library HLQ.PROCMAN.RULES. These members must be adapted to your Requirements. The importance of the members and the parameters are described in the following chapters.
xxSANA01
Will be used for JCL analysis and for definition of form attributes
PRXPRG
xxSGEN01
Will be used for JCL generation. Depending on the Rules the user is forced later on to make entries in the ProcMan web dialog.
PRCPRG
Last updated